<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Electrical Safety First Archives - Professional Electricians Wholesaler</title>
	<atom:link href="https://pewholesaler.co.uk/tag/electrical-safety-first/feed/" rel="self" type="application/rss+xml" />
	<link>https://pewholesaler.co.uk/tag/electrical-safety-first/</link>
	<description></description>
	<lastBuildDate>Wed, 12 Feb 2025 09:47:06 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.5</generator>
	<item>
		<title>Major seminar tackles challenges faced by electrical industry</title>
		<link>https://pewholesaler.co.uk/major-seminar-tackles-challenges-faced-by-electrical-industry/</link>
		
		<dc:creator><![CDATA[AdamHome]]></dc:creator>
		<pubDate>Thu, 13 Feb 2025 09:00:45 +0000</pubDate>
				<category><![CDATA[News]]></category>
		<category><![CDATA[Demand and Supply]]></category>
		<category><![CDATA[electrical industry]]></category>
		<category><![CDATA[electrical installation industry]]></category>
		<category><![CDATA[Electrical Safety First]]></category>
		<category><![CDATA[industry news]]></category>
		<category><![CDATA[seminar]]></category>
		<guid isPermaLink="false">https://pewholesaler.co.uk/?p=28358</guid>

					<description><![CDATA[<p>As the UK heads towards a low-carbon electrified future, the need for the electrical installation industry to modernise will be under the spotlight on 3rd April at the 2025 Electrical Installation Seminar, organised by Electrical Safety First. The theme for this year’s event is Demand and Supply and will focus on the issues associated with infrastructure modernisation and the increasing...</p>
<p>The post <a href="https://pewholesaler.co.uk/major-seminar-tackles-challenges-faced-by-electrical-industry/">Major seminar tackles challenges faced by electrical industry</a> appeared first on <a href="https://pewholesaler.co.uk">Professional Electricians Wholesaler</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="pewho-2484340163" class="pewho-before-content pewho-entity-placement"><!-- /111384791/pew-sponsored-leaderboard -->
    <div id='div-gpt-ad-1556702621284-0'>
    <script>
    googletag.cmd.push(function() { googletag.display('div-gpt-ad-1556702621284-0'); });
    </script>
    </div></div><h3>As the UK heads towards a low-carbon electrified future, the need for the electrical installation industry to modernise will be under the spotlight on 3rd April at the 2025 Electrical Installation Seminar, organised by Electrical Safety First.</h3>
<p>The theme for this year’s event is<em> Demand and Supply</em> and will focus on the issues associated with infrastructure modernisation and the increasing demands on the UK’s building stock.</p>
<p>Expert speakers will discuss how energy provisions and services are changing and the subsequent impact on the workforce in terms of safety, quality and competency requirements.</p><div id="pewho-3289160902" class="pewho-inline-mpu pewho-entity-placement"><!-- /111384791/pew-inline-mpu-1 - content after para 2 -->
<div id='div-gpt-ad-1551219974094-0' style="max-width: 300px; margin: 0 auto 20px;">
<script>
googletag.cmd.push(function() { googletag.display('div-gpt-ad-1551219974094-0'); });
</script>
</div>
</div>
<p>Held at the IET building in Central London, this leading industry event will feature a range of engaging presentations and panel discussions will highlight learnings from the UK’s energy transition to date, and considerations to be made now for a successful future. It brings together more than 100 experts and leaders to explore critical issues, solutions, and insights into safer electrical installation.</p>
<p>Luke Osborne, Deputy Technical Director of Electrical Safety First, said: “We encourage our speakers not only to share their concerns, but also offer best practice solutions, whilst looking to the future on upcoming developments in the electrical installation sector. The seminar is the perfect platform to share expertise, future-proof your business, get feedback about your ideas from fellow professionals, and meet potential clients.</p>
<p><strong>For more information and to book tickets, visit</strong> <a href="https://www.electricalsafetyfirst.org.uk/seminar" target="_blank" rel="noopener"><strong>electricalsafetyfirst.org.uk/seminar</strong></a></p>
<p><strong>Find more of the latest industry news <a href="https://pewholesaler.co.uk/category/news/" target="_blank" rel="noopener">here</a></strong></p>
<p>The post <a href="https://pewholesaler.co.uk/major-seminar-tackles-challenges-faced-by-electrical-industry/">Major seminar tackles challenges faced by electrical industry</a> appeared first on <a href="https://pewholesaler.co.uk">Professional Electricians Wholesaler</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>A Brief Overview of Conditions When Considering a Suitable Wiring System for an Electrical Installation</title>
		<link>https://pewholesaler.co.uk/a-brief-overview-of-conditions-when-considering-a-suitable-wiring-system-for-an-electrical-installation/</link>
		
		<dc:creator><![CDATA[Digital Assistant]]></dc:creator>
		<pubDate>Tue, 23 Apr 2024 08:00:10 +0000</pubDate>
				<category><![CDATA[News]]></category>
		<category><![CDATA[Opinion]]></category>
		<category><![CDATA[electrical installation]]></category>
		<category><![CDATA[Electrical Safety]]></category>
		<category><![CDATA[Electrical Safety First]]></category>
		<category><![CDATA[Jake Green]]></category>
		<category><![CDATA[Scolmore Group]]></category>
		<guid isPermaLink="false">https://pewholesaler.co.uk/?p=27220</guid>

					<description><![CDATA[<p>Jake Green, Head of Technical Engagement, Scolmore Group, gives a brief overview of the general range of conditions detailed in Section 522 of BS7671, which an installer will have to consider as they select a suitable wiring system for an electrical installation. One of the fundamental principles detailed in Chapter 13 of BS7671: 2018 (including...</p>
<p>The post <a href="https://pewholesaler.co.uk/a-brief-overview-of-conditions-when-considering-a-suitable-wiring-system-for-an-electrical-installation/">A Brief Overview of Conditions When Considering a Suitable Wiring System for an Electrical Installation</a> appeared first on <a href="https://pewholesaler.co.uk">Professional Electricians Wholesaler</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="pewho-2484340163" class="pewho-before-content pewho-entity-placement"><!-- /111384791/pew-sponsored-leaderboard -->
    <div id='div-gpt-ad-1556702621284-0'>
    <script>
    googletag.cmd.push(function() { googletag.display('div-gpt-ad-1556702621284-0'); });
    </script>
    </div></div><h3>Jake Green, Head of Technical Engagement, Scolmore Group, gives a brief overview of the general range of conditions detailed in Section 522 of BS7671, which an installer will have to consider as they select a suitable wiring system for an electrical installation.</h3>
<p>One of the fundamental principles detailed in Chapter 13 of BS7671: 2018 (including amendments) is ‘Environmental conditions’. Simply stated, Regulation 132.5.1 requires that “the design of the electrical installation shall take into account the environmental conditions to which it will be subjected”.</p>
<p><strong>Section 522</strong></p><div id="pewho-3289160902" class="pewho-inline-mpu pewho-entity-placement"><!-- /111384791/pew-inline-mpu-1 - content after para 2 -->
<div id='div-gpt-ad-1551219974094-0' style="max-width: 300px; margin: 0 auto 20px;">
<script>
googletag.cmd.push(function() { googletag.display('div-gpt-ad-1551219974094-0'); });
</script>
</div>
</div>
<p>Section 522 of BS7671 details those environmental conditions that need to be considered when selecting and installing wiring systems. The scope of the section is wide ranging covering the following:</p>
<ul>
<li><strong><em>Ambient temperature</em></strong> – requires the designer/installer to ensure that installed equipment is suitable for both the minimum and maximum temperatures reasonably expected. Account should also be taken of the maximum temperature expected under fault conditions (522.1).</li>
<li><strong><em>External heat sources</em></strong> – electrical equipment must be protected from the detrimental effects of specific heat sources. This might be by shielding, distancing from the source, having equipment capable of managing the level of heat or local reinforcement or substitution of insulating material (522.2).</li>
<li><strong><em>Presence of water or high humidity</em></strong> – electrical equipment must be suitably protected from ingress by water and/or the build-up of condensation. The Unicrimp Q-Nect series (junction boxes, connectors and connection boxes) provides a range of IP66 to IP68 products, providing the designer/installer with suitable options when selecting equipment for use in the presence of water (522.3).</li>
<li><strong><em>Presence of solid foreign bodies</em></strong> – requires the wiring system to be capable of minimising the danger arising from the ingress of solid foreign bodies. The IP rating should be suitable for the nature of the foreign bodies (522.4).</li>
<li><strong><em>Presence of corrosive or polluting substances</em></strong> – requires due account to be taken of materials/substances likely to cause corrosion or deterioration of the wiring system. This can be water (rust), presence of dissimilar metals or more obvious corrosive substances (522.5).</li>
<li><strong><em>Impact</em></strong> – the wiring system must be capable of withstanding damage caused by mechanical stress such as, impact, abrasion, penetration, tension, compression during installation as well as being protected from impact as part of the fixed installation (522.6).</li>
<li><strong><em>Vibration</em></strong> – requires a wiring system to be supported in such a way that due account is given to the likely vibration that will exist. This may require, for example, use to be made of saddle clips rather than standard cable clips where a cable is not installed within a cable management system (522.7).</li>
<li><strong><em>Other mechanical stresses</em></strong> – requires a wiring system to be selected and erected to avoid during installation, use or maintenance, damage to the sheath. This requires use to be made, where necessary of correct saddles, clips and the like to support cables to avoid damage to the cables and terminations. Furthermore, amongst other things, buried cables should be suitably marked with tape/cable covers (522.8).</li>
<li><strong><em>Presence of flora and/or mould growth</em></strong> – requires the designer to take account of the effects of plants, trees and the ingress of mould growth (522.9).</li>
<li><strong><em>Presence of fauna</em></strong> – recognises that wildlife can have a serious negative impact on an installation. Rodents can gain access through very small openings; large animals can cause significant damage to cables and the like. Designers and installers must make use of both suitable wiring systems and correct locations to avoid damage (522.10).</li>
<li><strong><em>Solar radiation and ultraviolet radiation</em></strong> – where solar or ultraviolet radiation is likely to have a significant effect, a suitable wiring system must be selected and erected or properly shielded (522.11).</li>
<li><strong><em>Seismic effects</em></strong> – are unlikely to be an issue in the UK (522.12).</li>
<li><strong><em>Movement or air</em></strong> (522.13) and <strong><em>Nature of processed or stored materials</em></strong> (522.14) is covered in other parts of BS7671.</li>
<li><strong><em>Building design</em></strong> – requires the designer to take due account of where structural movement is likely to exist and potentially create excessive mechanical stress. This typically happens in larger and taller buildings where relative movement is required as part of the build (522.15).</li>
</ul>
<p>This article has only touched upon the various environmental factors to be considered by designers and installers. Reference should also be made to Appendix 5 of BS7671for the applicability of the various codes detailed in Section 522.</p>
<p><strong>For more information, click <a href="http://www.rdr.link/was009" target="_blank" rel="noopener">here</a></strong></p>
<p>The post <a href="https://pewholesaler.co.uk/a-brief-overview-of-conditions-when-considering-a-suitable-wiring-system-for-an-electrical-installation/">A Brief Overview of Conditions When Considering a Suitable Wiring System for an Electrical Installation</a> appeared first on <a href="https://pewholesaler.co.uk">Professional Electricians Wholesaler</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>The vital role of safe isolation to ensure electrical security &#124; Kasp</title>
		<link>https://pewholesaler.co.uk/the-vital-role-of-safe-isolation-to-ensure-electrical-security-kasp/</link>
		
		<dc:creator><![CDATA[Digital Assistant]]></dc:creator>
		<pubDate>Thu, 28 Dec 2023 09:00:43 +0000</pubDate>
				<category><![CDATA[Features]]></category>
		<category><![CDATA[electrical]]></category>
		<category><![CDATA[Electrical Safety]]></category>
		<category><![CDATA[Electrical Safety First]]></category>
		<category><![CDATA[electrical security]]></category>
		<category><![CDATA[Electrician]]></category>
		<category><![CDATA[health and safety]]></category>
		<category><![CDATA[isolation]]></category>
		<category><![CDATA[Kasp]]></category>
		<category><![CDATA[Professional Electrician]]></category>
		<category><![CDATA[Professional Electricians Wholesaler]]></category>
		<category><![CDATA[safe isolation]]></category>
		<category><![CDATA[safety]]></category>
		<category><![CDATA[wholesaler news]]></category>
		<guid isPermaLink="false">https://pewholesaler.co.uk/?p=26720</guid>

					<description><![CDATA[<p>PEW hears from Kasp on the vital role of safe isolation in ensuring electrical security. In the world of electrical work, safe isolation is a fundamental part of an electrician’s role – not only to protect circuits but to protect people’s lives. While health and safety is already a top priority in high risk industries...</p>
<p>The post <a href="https://pewholesaler.co.uk/the-vital-role-of-safe-isolation-to-ensure-electrical-security-kasp/">The vital role of safe isolation to ensure electrical security | Kasp</a> appeared first on <a href="https://pewholesaler.co.uk">Professional Electricians Wholesaler</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="pewho-2484340163" class="pewho-before-content pewho-entity-placement"><!-- /111384791/pew-sponsored-leaderboard -->
    <div id='div-gpt-ad-1556702621284-0'>
    <script>
    googletag.cmd.push(function() { googletag.display('div-gpt-ad-1556702621284-0'); });
    </script>
    </div></div><h3><strong>PEW hears from Kasp on the vital role of safe isolation in ensuring electrical security.</strong></h3>
<p>In the world of electrical work, safe isolation is a fundamental part of an electrician’s role – not only to protect circuits but to protect people’s lives.</p>
<p>While health and safety is already a top priority in high risk industries like construction, those who work regularly with known hazards can sometimes become complacent. In the electrical sector – the safe isolation of the electrical network cannot be overlooked.</p><div id="pewho-3289160902" class="pewho-inline-mpu pewho-entity-placement"><!-- /111384791/pew-inline-mpu-1 - content after para 2 -->
<div id='div-gpt-ad-1551219974094-0' style="max-width: 300px; margin: 0 auto 20px;">
<script>
googletag.cmd.push(function() { googletag.display('div-gpt-ad-1551219974094-0'); });
</script>
</div>
</div>
<p>It’s an essential but often underestimated aspect of the job and is a key step in ensuring that workers on site aren’t exposed to danger when working on or near live electrical systems. Safe isolation is a multi-step process that involves not only turning off the power but also locking out the circuit to prevent accidental reactivation.</p>
<p>Sadly, over 1,000 electricity-related accidents are reported to the HSE every year, 30 of which lead to fatal injuries. When dealing with live electricity, there’s no room for error, the only way to ensure everyone’s safety is by adopting thorough isolation procedures.</p>
<p>The opportunity for electrical wholesalers is clear; encouraging the usage of appropriate lock off devices as an essential piece of kit for professional electricians to protect themselves and others from potentially deadly consequences. The supply of this equipment is not only an opportunity to generate sales, but an opportunity to save lives.</p>
<p><strong>Keep assets secure</strong></p>
<p>With over 40 years of security expertise under its belt, Kasp is one of the UK’s leading security padlock, chain, and cable brands, created by Carl Kammerling International Ltd.</p>
<p>Kasp Lockout is a range of essential tools designed specifically with safe isolation in mind, to protect electricians and their colleagues from accidents at work. Every year, thousands of injuries at work occur during the repair or maintenance of machinery, and most are due to a failure to isolate energy sources. Kasp Lockout safeguards against a sudden release of energy, locking off energy sources using padlocks and physical security devices.</p><div id="pewho-1353673017" class="pewho-inline-mpu-2 pewho-entity-placement"><!-- /111384791/pew-inline-mpu-2 - content after para 8 -->
<div id='div-gpt-ad-1551220000135-0' style="max-width: 300px; margin: 0 auto 20px;">
<script>
googletag.cmd.push(function() { googletag.display('div-gpt-ad-1551220000135-0'); });
</script>
</div></div>
<p><em> </em><em><strong>Kasp Easifit MCB Lockout</strong></em></p>
<p>This universal mini circuit breaker isolates single, double, and triple switches. Its simple installation uses no tools, and quickly protects against dangerous energy surges while maintenance and repairs are carried out.</p>
<p>To use, simply place the tool over the switch, tighten the easy-to-use thumb screw, rotate the screw toggle and lockout with a padlock. Made from quality, non-conductive material, the Kasp Easifit MCB Lockout is an essential part of any maintenance toolbox.</p>
<p><em><strong>Kasp 812 Pin Lockout</strong></em></p>
<p>Ideal for locking out wider miniature circuit breakers, this pin lockout uses a simple push button installation, so no tools are required. Made from high quality, non-conductive material, the pin lockout works with one padlock and fits a maximum shackle diameter of 6mm.</p>
<p><em><strong>Kasp MCB Lockout Kit</strong></em></p>
<p>This unique kit contains all the essential parts to lock off one mini circuit breaker. The kit includes an Easifit MCB Lockout, one 25mm brass padlock, a danger and identity tag, and a carabiner to hold the kit together. Essential Lockout Kit This kit is ideal for a broad range of circuit breakers, including those over 60 A. It’s easy to use and contains both the Easifit MCB Lockout and the Pin Out Wide Lockout. F</p>
<p>Fitting neatly into a sturdy red pouch with a carabiner for hands-free access, the kit also contains a 40mm red vinyl coloured brass padlock with brass shackle, a 25mm brass padlock, a lock off hasp, a tagout marker pen, and a danger tag.</p>
<p><strong>Protection for electrician’s assets</strong></p>
<p>According to Met Police data, nearly 35,000 tools were stolen in the capital city alone between January 2021 and October 2022. A third of those tools were stolen from vehicles. Kasp Van Locks provide the ultimate defence for tradespeople seeking to protect their vehicles.</p>
<p><strong>Kasp 500 Van Lock and Hasp</strong></p>
<p>Designed just for vans, the Kasp 500 Van Lock’s chrome plated hardened steel body gives incredible strength as well as protection from corrosion. A shrouded steel shackle offers the ultimate safeguard against hacksaw and cropping attacks, while its six-pin cylinder defends against lock picking.</p>
<p>With a corrosion resistant mechanism to protect against the elements, this is the ultimate van lock. Meanwhile, the hasp is made from zinc plated heavy duty steel, giving excellent security and protection against corrosion. It is supplied with fixing bolts and includes a nifty storage bracket to hold the padlock when the van is open.</p>
<p><strong>Conclusion</strong></p>
<p>Safe isolation is more than just a routine task for an electrician – it’s arguably the most important part of their role and demonstrates their commitment to prioritising the protection of others.</p>
<p>Electrical professionals should be actively encouraged to utilise the latest technologies and equipment available to them to make every day electrical work safer for all involved. The consequences of not doing so are simply too great.</p>
<p><strong>For more information, click <a href="http://www.rdr.link/wap007" target="_blank" rel="noopener">here</a></strong></p>
<p>The post <a href="https://pewholesaler.co.uk/the-vital-role-of-safe-isolation-to-ensure-electrical-security-kasp/">The vital role of safe isolation to ensure electrical security | Kasp</a> appeared first on <a href="https://pewholesaler.co.uk">Professional Electricians Wholesaler</a>.</p>