<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>protective devices Archives - Professional Electricians Wholesaler</title>
	<atom:link href="https://pewholesaler.co.uk/tag/protective-devices/feed/" rel="self" type="application/rss+xml" />
	<link>https://pewholesaler.co.uk/tag/protective-devices/</link>
	<description></description>
	<lastBuildDate>Wed, 26 Nov 2025 14:43:56 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>
	<item>
		<title>Why it&#8217;s crucial to ensure protective devices &#038; switchgear are correctly rated to handle high fault currents</title>
		<link>https://pewholesaler.co.uk/why-its-crucial-to-ensure-protective-devices-switchgear-are-correctly-rated-to-handle-high-fault-currents/</link>
		
		<dc:creator><![CDATA[AdamHome]]></dc:creator>
		<pubDate>Wed, 26 Nov 2025 09:00:00 +0000</pubDate>
				<category><![CDATA[Features]]></category>
		<category><![CDATA[Circuit Protection]]></category>
		<category><![CDATA[electrical faults]]></category>
		<category><![CDATA[high fault currents]]></category>
		<category><![CDATA[protective devices]]></category>
		<category><![CDATA[Scolmore Group]]></category>
		<category><![CDATA[Switchgear]]></category>
		<guid isPermaLink="false">https://pewholesaler.co.uk/?p=29218</guid>

					<description><![CDATA[<p>Jake Green, Head of Technical Engagement, Scolmore Group, looks at how electrical faults can generate high fault currents — and why it’s crucial to ensure protective devices and switchgear are correctly rated to handle them. In any electrical system, a fault &#8211; whether to Earth or between live conductors &#8211; will produce what’s known as...</p>
<p>The post <a href="https://pewholesaler.co.uk/why-its-crucial-to-ensure-protective-devices-switchgear-are-correctly-rated-to-handle-high-fault-currents/">Why it&#8217;s crucial to ensure protective devices &#038; switchgear are correctly rated to handle high fault currents</a> appeared first on <a href="https://pewholesaler.co.uk">Professional Electricians Wholesaler</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="pewho-4099350342" class="pewho-before-content pewho-entity-placement"><!-- /111384791/pew-sponsored-leaderboard -->
    <div id='div-gpt-ad-1556702621284-0'>
    <script>
    googletag.cmd.push(function() { googletag.display('div-gpt-ad-1556702621284-0'); });
    </script>
    </div></div><h3>Jake Green, Head of Technical Engagement, Scolmore Group, looks at how electrical faults can generate high fault currents — and why it’s crucial to ensure protective devices and switchgear are correctly rated to handle them.</h3>
<p>In any electrical system, a fault &#8211; whether to Earth or between live conductors &#8211; will produce what’s known as a fault current. The level of this current depends on a range of factors, including system voltage, number of phases, and how close the installation is to the distribution transformer.</p>
<p>For wholesalers and contractors, understanding these fault levels is key to selecting and supplying the right equipment. This article explores typical fault current scenarios, how they can be assessed, and why choosing products with the correct breaking capacity is vital for safe and compliant installations.</p><div id="pewho-773687099" class="pewho-inline-mpu pewho-entity-placement"><!-- /111384791/pew-inline-mpu-1 - content after para 2 -->
<div id='div-gpt-ad-1551219974094-0' style="max-width: 300px; margin: 0 auto 20px;">
<script>
googletag.cmd.push(function() { googletag.display('div-gpt-ad-1551219974094-0'); });
</script>
</div>
</div>
<p>In any electrical system a fault to Earth or a fault between live conductors will generate a fault current. The level of fault current will depend on a range of factors, including voltage levels, number of phases, proximity to the distribution transformer, and the like.</p>
<p>This article looks at likely levels of fault current, how they are to be assessed and the nature of equipment being sufficient to manage such fault currents (breaking capacity).</p>
<figure id="attachment_29226" aria-describedby="caption-attachment-29226" style="width: 600px" class="wp-caption aligncenter"><img fetchpriority="high" decoding="async" class="wp-image-29226" src="https://pewholesaler.co.uk/wp-content/uploads/2025/11/pic-1-3-phase-output-to-step-up-transformer-300x275.png" alt="" width="600" height="551" srcset="https://pewholesaler.co.uk/wp-content/uploads/2025/11/pic-1-3-phase-output-to-step-up-transformer-300x275.png 300w, https://pewholesaler.co.uk/wp-content/uploads/2025/11/pic-1-3-phase-output-to-step-up-transformer.png 660w" sizes="(max-width: 600px) 100vw, 600px" /><figcaption id="caption-attachment-29226" class="wp-caption-text">3 phase output to step up transformer</figcaption></figure>
<p><strong>Types of fault</strong></p>
<p>There are two types of ‘short circuit’ generally considered in BS 7671:</p>
<ul>
<li><em><strong>Earth fault current</strong></em> – a current resulting from a fault of negligible impedance between a line conductor and an exposed-conductive-part or a protective conductor.</li>
<li><em><strong>Short circuit</strong></em> – an overcurrent resulting from a fault of negligible impedance between live conductors having a difference in potential under normal operating conditions.</li>
</ul>
<figure id="attachment_29219" aria-describedby="caption-attachment-29219" style="width: 600px" class="wp-caption aligncenter"><img decoding="async" class="wp-image-29219" src="https://pewholesaler.co.uk/wp-content/uploads/2025/11/Picture-1-300x213.png" alt="" width="600" height="425" srcset="https://pewholesaler.co.uk/wp-content/uploads/2025/11/Picture-1-300x213.png 300w, https://pewholesaler.co.uk/wp-content/uploads/2025/11/Picture-1.png 625w" sizes="(max-width: 600px) 100vw, 600px" /><figcaption id="caption-attachment-29219" class="wp-caption-text">Figure 1 Potential faults</figcaption></figure>
<p><strong>Single-phase fault</strong></p>
<p>Based on <em>Figure 1</em> the level of fault current is determined by the following:</p><div id="pewho-384367577" class="pewho-inline-mpu-2 pewho-entity-placement"><!-- /111384791/pew-inline-mpu-2 - content after para 8 -->
<div id='div-gpt-ad-1551220000135-0' style="max-width: 300px; margin: 0 auto 20px;">
<script>
googletag.cmd.push(function() { googletag.display('div-gpt-ad-1551220000135-0'); });
</script>
</div></div>
<ul>
<li>The voltage – single phase (230 V)</li>
<li>The impedance of the transformer winding</li>
<li>The impedance of the supply cable (line-to-Earth or line-to-neutral)</li>
<li>The impedance of the internal cable (line-to-Earth or line-to-neutral)</li>
</ul>
<p>The simplest way to determine the level of fault current in a single-phase system is to determine the combined values of the transformer winding and the line and neutral conductors.</p>
<p><img decoding="async" class="alignnone size-full wp-image-29220" src="https://pewholesaler.co.uk/wp-content/uploads/2025/11/Screen-Shot-2025-11-25-at-11.06.55.png" alt="" width="147" height="49" /></p>
<p>This can be simplified to</p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-29221" src="https://pewholesaler.co.uk/wp-content/uploads/2025/11/Screen-Shot-2025-11-25-at-11.07.00.png" alt="" width="136" height="45" /></p>
<p><strong>Two-phase fault</strong></p>
<p>Based on <em>Figure 1</em> the level of fault current is determined by the following:</p>
<ul>
<li>The voltage – between two phases (400 V)</li>
<li>The impedance of the transformer winding.</li>
<li>The impedance of the supply cable (line-to-Earth or line-to-neutral).</li>
<li>The impedance of the internal cable (line-to-Earth or line-to-neutral.</li>
</ul>
<figure id="attachment_29229" aria-describedby="caption-attachment-29229" style="width: 600px" class="wp-caption aligncenter"><img loading="lazy" decoding="async" class="wp-image-29229" src="https://pewholesaler.co.uk/wp-content/uploads/2025/11/Picture6-supplies-and-voltages-300x235.png" alt="" width="600" height="470" srcset="https://pewholesaler.co.uk/wp-content/uploads/2025/11/Picture6-supplies-and-voltages-300x235.png 300w, https://pewholesaler.co.uk/wp-content/uploads/2025/11/Picture6-supplies-and-voltages.png 694w" sizes="auto, (max-width: 600px) 100vw, 600px" /><figcaption id="caption-attachment-29229" class="wp-caption-text">Supplies and voltages</figcaption></figure>
<p>The simplest way to determine the level of fault current between two-phases is to determine the combined values of the transformer winding and the line and line conductors.</p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-29222" src="https://pewholesaler.co.uk/wp-content/uploads/2025/11/Screen-Shot-2025-11-25-at-11.08.26.png" alt="" width="140" height="51" /></p>
<p>This can be simplified to</p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-29223" src="https://pewholesaler.co.uk/wp-content/uploads/2025/11/Screen-Shot-2025-11-25-at-11.08.30.png" alt="" width="145" height="46" /></p>
<p>The level of fault will be greater than for a single-phase fault but will not be double the value of a single-phase fault.</p>
<figure id="attachment_29227" aria-describedby="caption-attachment-29227" style="width: 600px" class="wp-caption aligncenter"><img loading="lazy" decoding="async" class="wp-image-29227" src="https://pewholesaler.co.uk/wp-content/uploads/2025/11/Picture5-resultant-voltage-in-a-star-connected-system-300x261.png" alt="" width="600" height="523" srcset="https://pewholesaler.co.uk/wp-content/uploads/2025/11/Picture5-resultant-voltage-in-a-star-connected-system-300x261.png 300w, https://pewholesaler.co.uk/wp-content/uploads/2025/11/Picture5-resultant-voltage-in-a-star-connected-system.png 584w" sizes="auto, (max-width: 600px) 100vw, 600px" /><figcaption id="caption-attachment-29227" class="wp-caption-text">Resultant voltage in a star connected system</figcaption></figure>
<p><strong>Three-phase fault</strong></p>
<p>Based on <em>Figure 1</em> the level of fault current is determined by the following:</p>
<ul>
<li>The voltage – counter-intuitively this is taken to be the value of a single-phase supply (230 V)</li>
<li>The impedance of the transformer winding.</li>
<li>The impedance of the supply cable (line only).</li>
</ul>
<p>The simplest way to determine the level of fault current between three-phases is to determine the combined values of the transformer winding and the line conductor.</p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-29224" src="https://pewholesaler.co.uk/wp-content/uploads/2025/11/Screen-Shot-2025-11-25-at-11.10.21.png" alt="" width="113" height="54" /></p>
<p>&nbsp;</p>
<p>This can be simplified to</p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-29225" src="https://pewholesaler.co.uk/wp-content/uploads/2025/11/Screen-Shot-2025-11-25-at-11.10.24.png" alt="" width="106" height="50" /></p>
<p>&nbsp;</p>
<p>The level of fault will be greater than for a single-phase fault, and a two-phase fault but will still not be double the value of a single-phase fault.</p>
<figure id="attachment_29228" aria-describedby="caption-attachment-29228" style="width: 600px" class="wp-caption aligncenter"><img loading="lazy" decoding="async" class="wp-image-29228" src="https://pewholesaler.co.uk/wp-content/uploads/2025/11/Picture2-generated-three-phase-supply-300x247.png" alt="" width="600" height="493" srcset="https://pewholesaler.co.uk/wp-content/uploads/2025/11/Picture2-generated-three-phase-supply-300x247.png 300w, https://pewholesaler.co.uk/wp-content/uploads/2025/11/Picture2-generated-three-phase-supply.png 597w" sizes="auto, (max-width: 600px) 100vw, 600px" /><figcaption id="caption-attachment-29228" class="wp-caption-text">Generated three phase supply</figcaption></figure>
<p>Understanding the difference between expected fault current levels is important when selecting electrical equipment, such as circuit-breakers, switches and the like.</p>
<p>In a subsequent article we will consider the impact of prospective fault current values on the choice of equipment and recognise the importance of ensuring that the correct breaking capacity is selected.</p>
<p><strong>For further information, click <a href="http://www.rdr.link/wbi007" target="_blank" rel="noopener">here</a></strong></p>
<p><strong>Find more industry features <a href="https://pewholesaler.co.uk/category/features/" target="_blank" rel="noopener">here</a></strong></p>
<p>The post <a href="https://pewholesaler.co.uk/why-its-crucial-to-ensure-protective-devices-switchgear-are-correctly-rated-to-handle-high-fault-currents/">Why it&#8217;s crucial to ensure protective devices &#038; switchgear are correctly rated to handle high fault currents</a> appeared first on <a href="https://pewholesaler.co.uk">Professional Electricians Wholesaler</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Elucian &#124; Rcbos</title>
		<link>https://pewholesaler.co.uk/elucian-rcbos/</link>
		
		<dc:creator><![CDATA[Digital Assistant]]></dc:creator>
		<pubDate>Tue, 31 Oct 2023 11:00:39 +0000</pubDate>
				<category><![CDATA[Products]]></category>
		<category><![CDATA[Electrician]]></category>
		<category><![CDATA[Elucian]]></category>
		<category><![CDATA[Elucian RCBOs]]></category>
		<category><![CDATA[neutral conductors]]></category>
		<category><![CDATA[Pole C Curve]]></category>
		<category><![CDATA[protective devices]]></category>
		<category><![CDATA[Rcbos]]></category>
		<guid isPermaLink="false">https://pewholesaler.co.uk/?p=26407</guid>

					<description><![CDATA[<p>Scolmore continues to expand its Elucian consumer unit range to provide electricians with the broadest possible range of units and protective devices to cater for all installation requirements. New to the range is a 25A rated RCBO which joins the extensive protective devices line-up. An RCBO protects against a residual current or earth leakage when...</p>
<p>The post <a href="https://pewholesaler.co.uk/elucian-rcbos/">Elucian | Rcbos</a> appeared first on <a href="https://pewholesaler.co.uk">Professional Electricians Wholesaler</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="pewho-3617801211" class="pewho-before-content pewho-entity-placement"><!-- /111384791/pew-sponsored-leaderboard -->
    <div id='div-gpt-ad-1556702621284-0'>
    <script>
    googletag.cmd.push(function() { googletag.display('div-gpt-ad-1556702621284-0'); });
    </script>
    </div></div><h3>Scolmore continues to expand its Elucian consumer unit range to provide electricians with the broadest possible range of units and protective devices to cater for all installation requirements.</h3>
<p>New to the range is a 25A rated RCBO which joins the extensive protective devices line-up.</p>
<p>An RCBO protects against a residual current or earth leakage when there is a break in a circuit through poor electrical wiring or an incident such as drilling through a cable. An RCBO also protects against an overcurrent in the form of an overload when too many devices are in use in the circuit, drawing an amount of power which exceeds the capacity of the breaker, or a short circuit which occurs when there is a short between the line and neutral conductors.</p><div id="pewho-2420639727" class="pewho-inline-mpu pewho-entity-placement"><!-- /111384791/pew-inline-mpu-1 - content after para 2 -->
<div id='div-gpt-ad-1551219974094-0' style="max-width: 300px; margin: 0 auto 20px;">
<script>
googletag.cmd.push(function() { googletag.display('div-gpt-ad-1551219974094-0'); });
</script>
</div>
</div>
<p>The Elucian RCBOs are compact single module devices that allow for additional space above to make it easier to install and terminate outgoing circuits. These devices are Type A rated offering a resilience when DC current is present.</p>
<p>The RCBO protective devices range comprises:</p>
<p>Type A Single Pole B Curve – 6A,10A,16A, 20A, (new 25A), 32A and 40A.</p>
<p>Type A 2 Module Double Pole B Curve – 45A, 50A and 63A.</p>
<p>Type A Single Pole C Curve.</p>
<p>Type A Double Pole C Curve.</p><div id="pewho-1671589018" class="pewho-inline-mpu-2 pewho-entity-placement"><!-- /111384791/pew-inline-mpu-2 - content after para 8 -->
<div id='div-gpt-ad-1551220000135-0' style="max-width: 300px; margin: 0 auto 20px;">
<script>
googletag.cmd.push(function() { googletag.display('div-gpt-ad-1551220000135-0'); });
</script>
</div></div>
<p><strong>For more information, click <a href="http://www.rdr.link/wan014" target="_blank" rel="noopener">here</a></strong></p>
<p>The post <a href="https://pewholesaler.co.uk/elucian-rcbos/">Elucian | Rcbos</a> appeared first on <a href="https://pewholesaler.co.uk">Professional Electricians Wholesaler</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How are Hager&#8217;s protective devices supporting electrical contractors?</title>
		<link>https://pewholesaler.co.uk/how-are-hagers-protective-devices-supporting-electrical-contractors/</link>
		
		<dc:creator><![CDATA[AdamHome]]></dc:creator>
		<pubDate>Tue, 24 Jan 2023 09:00:06 +0000</pubDate>
				<category><![CDATA[Features]]></category>
		<category><![CDATA[AFDDs]]></category>
		<category><![CDATA[Amendment 2]]></category>
		<category><![CDATA[electrical contractors]]></category>
		<category><![CDATA[Hager]]></category>
		<category><![CDATA[protective devices]]></category>
		<category><![CDATA[SPDs]]></category>
		<guid isPermaLink="false">https://pewholesaler.co.uk/?p=25079</guid>

					<description><![CDATA[<p>Hager outlines some of the ways it is remaining compliant with new regulations and transforming the future of protection devices for the electrician. September 28th saw the previous amendment withdrawn and the changes outlined in Amendment 2 of the 18th Edition Wiring Regulations implemented. The new regulations further strengthen previous rules and include an increased...</p>
<p>The post <a href="https://pewholesaler.co.uk/how-are-hagers-protective-devices-supporting-electrical-contractors/">How are Hager&#8217;s protective devices supporting electrical contractors?</a> appeared first on <a href="https://pewholesaler.co.uk">Professional Electricians Wholesaler</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="pewho-154318413" class="pewho-before-content pewho-entity-placement"><!-- /111384791/pew-sponsored-leaderboard -->
    <div id='div-gpt-ad-1556702621284-0'>
    <script>
    googletag.cmd.push(function() { googletag.display('div-gpt-ad-1556702621284-0'); });
    </script>
    </div></div><h3>Hager outlines some of the ways it is remaining compliant with new regulations and transforming the future of protection devices for the electrician.</h3>
<p>September 28th saw the previous amendment withdrawn and the changes outlined in Amendment 2 of the 18th Edition Wiring Regulations implemented. The new regulations further strengthen previous rules and include an increased focus on the use of Arc Fault Detection Devices and Surge Protection Devices.</p>
<p><strong>Surge Protection Devices (SPD)</strong></p><div id="pewho-2813249378" class="pewho-inline-mpu pewho-entity-placement"><!-- /111384791/pew-inline-mpu-1 - content after para 2 -->
<div id='div-gpt-ad-1551219974094-0' style="max-width: 300px; margin: 0 auto 20px;">
<script>
googletag.cmd.push(function() { googletag.display('div-gpt-ad-1551219974094-0'); });
</script>
</div>
</div>
<p>With an increased focus on equipment protection against surge transient voltages, the latest regulations now require protection against transient overvoltages to be provided where the consequence caused by the overvoltage could result in:</p>
<p>(i) serious injury to, or loss of, human life</p>
<p>(ii) failure of a safety service, as defined in Part 2</p>
<p>(iii) significant financial or data loss</p>
<p>To support electrical contractors to reduce installation times, meet compliance responsibilities, and alleviate the need to purchase and fit separate protection devices for consumer units, the industry can benefit from Hager’s factory fitted and fully integrated SPD board to provide optimum surge protection performance.</p>
<p><strong>Patented connection</strong></p><div id="pewho-2770614228" class="pewho-inline-mpu-2 pewho-entity-placement"><!-- /111384791/pew-inline-mpu-2 - content after para 8 -->
<div id='div-gpt-ad-1551220000135-0' style="max-width: 300px; margin: 0 auto 20px;">
<script>
googletag.cmd.push(function() { googletag.display('div-gpt-ad-1551220000135-0'); });
</script>
</div></div>
<p>Benefitting from a number of features to improve surge protection effectiveness, including a patented busbar connection system, installers can be assured that fitting a Hager consumer unit with integrated surge protection guarantees the very best protection.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-25081 size-full" src="https://pewholesaler.co.uk/wp-content/uploads/2023/01/SPD-highlighted-1000x720-image-1.jpg" alt="" width="1000" height="720" srcset="https://pewholesaler.co.uk/wp-content/uploads/2023/01/SPD-highlighted-1000x720-image-1.jpg 1000w, https://pewholesaler.co.uk/wp-content/uploads/2023/01/SPD-highlighted-1000x720-image-1-300x216.jpg 300w, https://pewholesaler.co.uk/wp-content/uploads/2023/01/SPD-highlighted-1000x720-image-1-768x553.jpg 768w" sizes="auto, (max-width: 1000px) 100vw, 1000px" /></p>
<p><strong>Fully integrated </strong></p>
<p>Eliminating the need to purchase and fit separate protection devices for consumer units, with Hager’s factory-fitted and fully integrated SPD board no secondary upstream protection devices are required. Whilst surge protection devices previously required an MCB or fuses in the consumer unit to provide backup protection using one of the outgoing ways, Hager’s integrated solution removes this requirement, freeing up space in the consumer unit.</p>
<p>Additionally, Hager’s solution has CT2 construction type arrangements, ensuring that SPD devices are applicable for all common UK earthing arrangements such as TN-C-S (PME), TN-S and TT earthing systems, removing the risk of incorrect selection.</p>
<p><strong>Arc Fault Detection Devices (AFDD)</strong></p>
<p>Another notable change to the regulations is that AFDDs are now mandatory for use in certain settings; higher risk residential buildings, houses of multiple occupation, purpose-built student accommodation and care homes. For all other premises, the use of AFDDs is recommended for single-phase AC final circuits supplying socket outlets not exceeding 32A.</p>
<p>Hager’s latest AFDD with ProTools is ideally placed to support installers in shaping the electrical world of tomorrow, offering tangible installation benefits, as well as providing peace of mind for installers and end users seeking the best protection with this game changing device.</p>
<p><strong>In-situ software upgrades</strong></p>
<p>The new advanced ProTools diagnostic software offers superior safety protection levels, minimising time spent conducting fault finding. The ability to perform in-situ software updates via Bluetooth connectivity eliminates the need to remove or replace the device in the future and overcomes the traditional difficulty of diagnosing and resolving unwanted or operational trips manually. Thanks to additional safety aspects, the AFDD does not need the circuit to be re-energised when tripped to be able to identify the cause of the fault and leaves the consumer unit in a safe condition as fault finding occurs.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-25082 size-full" src="https://pewholesaler.co.uk/wp-content/uploads/2023/01/Screen-Shot-2023-01-13-at-10.51.34.png" alt="" width="817" height="818" srcset="https://pewholesaler.co.uk/wp-content/uploads/2023/01/Screen-Shot-2023-01-13-at-10.51.34.png 817w, https://pewholesaler.co.uk/wp-content/uploads/2023/01/Screen-Shot-2023-01-13-at-10.51.34-300x300.png 300w, https://pewholesaler.co.uk/wp-content/uploads/2023/01/Screen-Shot-2023-01-13-at-10.51.34-150x150.png 150w, https://pewholesaler.co.uk/wp-content/uploads/2023/01/Screen-Shot-2023-01-13-at-10.51.34-768x769.png 768w" sizes="auto, (max-width: 817px) 100vw, 817px" /></p>
<p><strong>Onboard diagnostics</strong></p>
<p>In the scenario that the Hager device trips, the cause for the disconnected circuit can be identified at the push of a button on the front of the device. With the ability to confirm eight statuses, the device can instantly detect if a series arc, parallel arc, overvoltage, residual current fault, overload, short circuit, AFDD failure or manual trip has occurred, saving time for installers, and improving overall diagnostic ability.</p>
<p><strong>Backwards compatibility</strong></p>
<p>Where AFDD devices were previously two modules wide in construction, Hager’s latest generation of AFDD has evolved, taking on the form of a single module wide device, available in both RCBO/AFDD and MCB/AFDD configurations and is a key part of Hager’s strategy to ensure devices are in many cases backwards compatible. In addition to the RCBO/AFDD, the MCB/AFDD solution also enables Hager installers to upgrade existing MCB installations to AFDD on the appropriate circuits, without having to upgrade the whole installation to RCBO configuration, providing minimal disruption.</p>
<p><strong>Future proofing</strong></p>
<p>With the rapid advancement of new technologies, it is possible that an electrical goods manufacturer of tomorrow may create an electrical device or appliance with a different waveform signature, thus creating a new signature and causing unwanted tripping. In anticipation of this, with ProTools In-Situ Software Upgrades, Hager’s AFDD solution can be intelligently modified to update the algorithm to accommodate new product signatures. These updates can be sent directly to mobile devices via the Hager Pilot app, allowing connection to the AFDD through Bluetooth technology to perform a software upgrade remotely. The ability to upgrade AFDD software in this way is a game changer for the industry.</p>
<p>As the reality of the Amendment 2 changes set in, Hager are committed to supporting the industry and have developed numerous resources to assist contractors with the transition, including the launch of the dedicated Amendment 2 Hub. Following the regulation changes, electrical contractors need to be mindful of the best practice solutions to ensure mandated and recommended responsibilities are met where the use of protection devices are concerned. Hager’s range of AFDD and SPD solutions, coupled with industry leading technical expertise, can fully support the attainment of these important regulation changes and help transform the future protection devices.</p>
<p><strong>To access the Hub and download supporting materials relating to the latest regulations, click <a href="http://www.rdr.link/wae011" target="_blank" rel="noopener">here</a></strong></p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-25080 size-full" src="https://pewholesaler.co.uk/wp-content/uploads/2023/01/hub-solutions.jpg" alt="" width="842" height="595" srcset="https://pewholesaler.co.uk/wp-content/uploads/2023/01/hub-solutions.jpg 842w, https://pewholesaler.co.uk/wp-content/uploads/2023/01/hub-solutions-300x212.jpg 300w, https://pewholesaler.co.uk/wp-content/uploads/2023/01/hub-solutions-768x543.jpg 768w" sizes="auto, (max-width: 842px) 100vw, 842px" /></p>
<p>The post <a href="https://pewholesaler.co.uk/how-are-hagers-protective-devices-supporting-electrical-contractors/">How are Hager&#8217;s protective devices supporting electrical contractors?</a> appeared first on <a href="https://pewholesaler.co.uk">Professional Electricians Wholesaler</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
